Applies to: QNO-C6083R
Issue Summary
Multiple profiles are configured and used for event and continuous recording on sites where Hanwha network cameras were linked with Genetec. However, the camera video sometimes does not play in Genetec VMS, with the network cameras displaying the following pop-up message:
ConfigChange log messages were repeatedly generated in the System LOG.
The problem occurred when Genetec VMS attempted to stream high-resolution H.265 video from the camera web page. For H.265 codec, the camera webpage supports video playback up to 720p. The web page attempted to change the video to a playable 720p resolution while Genetec VMS attempted to restore the resolution to 1080p.
Resolution
To correct errors with Genetec video playback:
- Maintain an up-to-date browser.
- Ensure that the camera firmware is current.
- Use H.264 codec or change the resolution from 1080p to 720p.