# Power, # Ground, # Short circuit
# QRN-830S/430S
1. Installation Cases
- The NVR models were installed in office.
2. Symptoms
- There is a voltage difference between NVR Cover and building ground
- The neutral-to-earth voltage (NEV) is mistaken for leakage voltage
* Neutral-to-Earth Voltage: It is an invalid power voltage caused by the potential difference between the neutral terminal and the earth when the earth is not connected (this phenomenon is not a defect in the product)
3. Causes
- The NVR ground terminal was not connected.
4. Measures
- Follow the installation guide: Use the Ground terminal for ground connection.