The below article is a guide for setting up the SolidEdge cameras, PNV-A6081R-E1T and PNV-A6081R-E2T in Wisenet WAVE
Once the camera has been set up and an IP address has been assigned (whether by DHCP or static), the camera's storage will need to be configured.
Select 'Start' under App installation to start the server. This should then disable the option to initialise/format the SSD storage.
Please note in order to start the WAVE services, the WAVE server needs to be installed. More details can be found here: WAVE Install
Users will need to use the device's IP as the server IP and assign the server port (by default 7001), and then enter the camera's credentials.
If it is a first time connection, the user will be asked to confirm said connection like so:
Once connected, it will be shown as:
Under the license page the license should then appear and can be activated for the camera:
The storage space should be identical to the free space available in the camera:
Please note, that stopping the WAVE service in the camera's storage setup page will disconnect the camera in WAVE. Once started the connection will be re-established.