Recent activity by Elliot Leem-
SolidEdge - Add Partition
The below article instructs users how to add partitions on our SolidEdge cameras, PNV-A6081R-E1T and PNV-A6081R-E2TA partition is a reserved part of the storage drive such as an SSD that is used a...
-
Firmware Update Failure - Recorders
This article outlines how to resolve a firmware update issue on a newly configured recorder Users may receive the below error when attempting to update the firmware (software) version of a reco...
-
What ports need to be opened to connect to a DVR/NVR remotely
The RTSP and HTTP ports of the DVR/NVR need to be open/port forwarded on your router, in order to connect to the DVR/NVR remotely via Wisenet Mobile or a VMS The RTSP and HTTP ports are 558 and 80...
-
NAS Recommended Specs
1. SMB versions - Q series: SMB 1.0 - X series: SMB 1.0 - P series: SMB 3.0 2. Shared Folder Size Limitations - We do not recommend over 2TB per folder. 3. Recommended NAS products - ...
-
SPC-2000/2001 compatibility with Wisenet NVRs
Generally, Wisenet Controllers (SPC series) via USB port were compatible with CMS (e.g SSM) in Windows PC only. Please refer to the below diagram. However, since x86 Intel NVRs (e.g PRN-6400), S...
-
SD Card Formatting
If a camera SD card is causing issues it is recommended to format the SD card, you can do this on the camera itself: Or on a PC/laptop using the SD Card Formatter: Which can be downloade...
-
Relay control on PNV-A9081R Camera
Many Wisenet cameras offers alarm inputs and outputs, these are TTL outputs and are not volt free, a transistorised relay is required to obtain a volt free output. The PNV-A9081R has a 12V 50mA su...
-
Relay control on PNV-A9081RLP Road-Ai Camera
Many Wisenet cameras offers alarm inputs and outputs, these are TTL outputs and are not volt free, a transistorised relay is required to obtain a volt free output. The PNV-A9081RLP Road-Ai ANPR ca...
-
Polycarbonate Bubble Maintenance
As manufacturers of PTZ and fixed dome cameras, we are frequently asked what to use to clean the polycarbonate bubbles and help shed rain droplets. Some integrators report using Rain-X, Windex, Le...
-
Relay control on SPM-4210 I/O Box
Many Wisenet devices offers alarm inputs and outputs, these are TTL outputs and are not volt free, a transistorised relay is required to obtain a volt free output. The SPM-4210 is a network attach...